Welcome to Starter Motors & Alternators Division

Overview

Starter Motors & Alternators Division is an Indian auto electric company supplying to various OEM customers in India and abroad. Starter Motors & Alternators Division manufactures GRS Starter Motors & Alternators with technology from Magneton – Czech Republic. We cater to the Tractors, Agriculture Machinery, Stationary Engine & Construction Equipment in India & Europe.

Starter Motors

Currently, Our Starter Motors & Alternators Division Starter motors are built based on the latest technology known as Gear-Reduction Technology. These GRS technology Starters are fast replacing Direct-Drive technology Starter motors in various segments. This GRS design Starter motors are lesser in weight, and compact in dimensions, compare to Direct-Drive design. This technology delivers high specific torque and starting speed, and efficient faster start ability of engine, making it a best choice for OEM Customers off late.

  • Lighter in Weight compare to Direct-Drive Starter motors
  • Compactness & its weight achieves less Packaging space on any vehicle
  • High Specific Torque and Speed starts engine at very faster rate
  • Enhances Battery life due to its less current drawn by Starter motor
  • Easy to Service and lower maintenance cost

Alternators

Our Starter Motors & Alternators Division Alternators are built based on the current Conventional designs with External Fan and Internal Fan types. These are classical and ventilated versions, that are used in various segments like Tractors, Farming equipment and Stationary engines. These Alternators are built with utmost care for ensuring stability of Output for continuous charging to battery, while operating under different working environments and applications.

  • Higher output at Idle speed, benefits continuous charging to Battery
  • High quality Power diodes’ Zener type used, those suppress voltage spikes from vehicle circuitry
  • Rectifier Diodes are built thru Welded process for better strength & withstand vibrations
  • High performance multi-function & mono-function regulator
  • Compact in size and classic design, to suit every contemporary vehicle

Manufacturing Facilities

Body Assembly   Solenoid   Armature   Pinion Drive Assembly

Online 100% Tests for Starter Motors

Armature Coil Resistance
Surge
High Voltage Flash
Stator Body Coil Resistance
Surge
High Voltage Flash
Solenoid Pull in Test
Hold on Test
Milli Volt Drop Test
Winding Balance Test
Insulation Test
Primary & Secondary Travel Check
Temperature Compensation
Air Leakage Test
Pinion Drive Assembly Ultrasonic Cleaning of Component
Inspection of Smooth Movement of one-way Clutch
Slippage Torque Checking
Final Assembly No Load Performance
Load Performance
Lock/Stall Test
Min. Operating Voltage

Alternator   Rotor   Stator   Rectifier   Regulator

Online 100% Tests for Alternators

Rotor Resistance
Surge
High Voltage Flash
Stator Coil Resistance
Surge
High Voltage Flash
Rectifier Forward Continuity Test
Reverse Leakage Test
Regulator Diode Drop Test
OCV Test
Droop Test
Frequency Test
Flash Test
Final Assembly Rotor Energization
Cut in Speed Test
Output @ Different Speed
Regulating Voltage
Zero Out Put Test
Blocking Diode Test
+ Starter Motor and Its Sub Assembly

Body Assembly   Solenoid   Armature   Pinion Drive Assembly

Online 100% Tests for Starter Motors

Armature Coil Resistance
Surge
High Voltage Flash
Stator Body Coil Resistance
Surge
High Voltage Flash
Solenoid Pull in Test
Hold on Test
Milli Volt Drop Test
Winding Balance Test
Insulation Test
Primary & Secondary Travel Check
Temperature Compensation
Air Leakage Test
Pinion Drive Assembly Ultrasonic Cleaning of Component
Inspection of Smooth Movement of one-way Clutch
Slippage Torque Checking
Final Assembly No Load Performance
Load Performance
Lock/Stall Test
Min. Operating Voltage
+ Alternator and Its Sub Assembly

Alternator   Rotor   Stator   Rectifier   Regulator

Online 100% Tests for Alternators

Rotor Resistance
Surge
High Voltage Flash
Stator Coil Resistance
Surge
High Voltage Flash
Rectifier Forward Continuity Test
Reverse Leakage Test
Regulator Diode Drop Test
OCV Test
Droop Test
Frequency Test
Flash Test
Final Assembly Rotor Energization
Cut in Speed Test
Output @ Different Speed
Regulating Voltage
Zero Out Put Test
Blocking Diode Test

State of art facilities having efficient process flow and latest machinery having capacity of more than 500,000 sets of Starter Motor and Alternator per annum.

  • Armature Inspection
  • Starter Body Line
  • Starter Motor Assembly Line
  • Alternator Rotor Line
  • Solenoid Assembly
  • Endurance Lab
  • Starter Solenoid Assembly
  • Stores

Plant locations

Bawal